Exchanger, heat
Use this image
Can I reuse this image without permission? Yes
Object images on the Ingenium Collection’s portal have the following Creative Commons license:
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUTE THIS IMAGE
Ingenium,
2002.0566.001
Permalink:
Ingenium is releasing this image under the Creative Commons licensing framework, and encourages downloading and reuse for non-commercial purposes. Please acknowledge Ingenium and cite the artifact number.
DOWNLOAD IMAGEPURCHASE THIS IMAGE
This image is free for non-commercial use.
For commercial use, please consult our Reproduction Fees and contact us to purchase the image.
- OBJECT TYPE
- blood/Heimbecker
- DATE
- 1958
- ARTIFACT NUMBER
- 2002.0566.001
- MANUFACTURER
- Canadian Pipe & Steel Fabricators
- MODEL
- Unknown
- LOCATION
- Toronto, Ontario, Canada
More Information
General Information
- Serial #
- prototype
- Part Number
- 1
- Total Parts
- 1
- AKA
- N/A
- Patents
- N/A
- General Description
- stainless steel
Dimensions
Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.
- Length
- 61.7 cm
- Width
- N/A
- Height
- N/A
- Thickness
- N/A
- Weight
- N/A
- Diameter
- 13.5 cm
- Volume
- N/A
Lexicon
- Group
- Medical Technology
- Category
- Medical equipment
- Sub-Category
- N/A
Manufacturer
- AKA
- Canadian Pipe
- Country
- Canada
- State/Province
- Ontario
- City
- Toronto
Context
- Country
- Canada
- State/Province
- Ontario
- Period
- Used 1958-1963.
- Canada
-
Designed by Dr. Raymond Heimbecker, at Banting Institute surgical research laboratory. The blood-heat exchanger and oxygenator were successfully used in 1958 for the first adult open heart operation in Canada . Used with oxygenator 2002.0565 in open heart surgery at Toronto General Hospital from 1958-63. Manufactured by Canadian Pipe & Steel Fabricators, Toronto. - Function
-
To maintain precise temperature of blood circulating through human body during surgery. - Technical
-
Blood-heat exchanger designed to maintain the precise control of blood temperature: body temperature of patient is consequently regulated. Thermostat can also produce rapid cooling and warming of patient, thus lowering their metabolic rate. Intake and output of oxygenated blood took place through two threaded openings on cylinder. Inside the cylinder are twenty pipes, through which the blood is circulated. Oxygenated (purified) blood was returned to the patient via their aorta canula. - Area Notes
-
Unknown
Details
- Markings
- UHN catalogue no. "995.3.1" printed by hand in black ink on one end.
- Missing
- None.
- Finish
- Bright stainless-steel finish on all exterior surfaces.
- Decoration
- N/A
CITE THIS OBJECT
If you choose to share our information about this collection object, please cite:
Canadian Pipe & Steel Fabricators, Exchanger, heat, 1958, Artifact no. 2002.0566, Ingenium – Canada’s Museums of Science and Innovation, http://collections.ingeniumcanada.org/en/id/2002.0566.001/
FEEDBACK
Submit a question or comment about this artifact.