Laser
Utiliser cette image
Puis-je réutiliser cette image sans autorisation? Oui
Les images sur le portail de la collection d’Ingenium ont la licence Creative Commons suivante :
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUER CETTE IMAGE
Ingenium,
2010.0304.010
Permalien:
Ingenium diffuse cette image sous le cadre de licence Creative Commons et encourage son téléchargement et sa réutilisation à des fins non commerciales. Veuillez mentionner Ingenium et citer le numéro de l’artefact.
TÉLÉCHARGER L’IMAGEACHETER CETTE IMAGE
Cette image peut être utilisée gratuitement pour des fins non commerciales.
Pour un usage commercial, veuillez consulter nos frais de reproduction et communiquer avec nous pour acheter l’image.
- TYPE D’OBJET
- S/O
- DATE
- Inconnu
- NUMÉRO DE L’ARTEFACT
- 2010.0304.010
- FABRICANT
- Inconnu
- MODÈLE
- Inconnu
- EMPLACEMENT
- Inconnu
Plus d’information
Renseignements généraux
- Nº de série
- S/O
- Nº de partie
- 10
- Nombre total de parties
- 11
- Ou
- Laser box
- Brevets
- S/O
- Description générale
- Metal casing; synthetic grey cables; black synthetic connectors with metal hardware and orange synthetic cables with metal connectors.
Dimensions
Remarque : Cette information reflète la taille générale pour l’entreposage et ne représente pas nécessairement les véritables dimensions de l’objet.
- Longueur
- 44,0 cm
- Largeur
- 43,0 cm
- Hauteur
- 23,0 cm
- Épaisseur
- S/O
- Poids
- S/O
- Diamètre
- S/O
- Volume
- S/O
Lexique
- Groupe
- Technologie médicale
- Catégorie
- Instruments
- Sous-catégorie
- S/O
Fabricant
- Ou
- Inconnu
- Pays
- Inconnu
- État/province
- Inconnu
- Ville
- Inconnu
Contexte
- Pays
- Canada
- État/province
- Manitoba
- Période
- Inconnu
- Canada
-
Viewed as a whole, the system is an example of purely Canadian technological innovation. Evolving out of a PhD thesis, SPY underwent experimental set up, prototyping, clinical testing, Canadian regulatory approvals, FDA approvals and manufacturing (Novadaq was spun off from the NRC and formed in 2000). The technology was developed at the NRC Institute for Biodiagnostics by Dr. John Docherty and (then) graduate student Rick Mangat (SPY formed his PhD thesis while at the University of Manitoba). Secondly, following an application to the Manitoba Blue Cross for a study in pigs, SPY was clinically tested at the Ottawa Heart Institute with input from Dr. Wilbur Keon and at the Sunnybrook Hospital in Toronto under Dr. Stephen Fremes. - Fonction
-
When the power is turned on all computer components become active, the imaging device laser becomes enable once the key is inserted into key-lock next to the Power Switch and turn as indicated to turn on the laser. - Technique
-
SPY imaging is the first technology available to cardiac surgeons to easily assess graft patency while the patient is on the operating table, and therefore allows for the correction of problems before closing the incision. Prior to this system, the standard was X-ray contrast angiography. Large, expensive and cumbersome, this technique exposed patients who would have compromised renal function during surgery to the dangers of X-rays.The use of ICG dye injected into patients is integral to the system. The absorption and emission spectra of ICG falls within the near infrared (NIR) portion of the optical spectrum in which there is the fewest substances in the body that absorb light. The result is a light that penetrates deeper into tissues, providing surgeons with improved imaging of vessels. - Notes sur la région
-
Inconnu
Détails
- Marques
- Mfr's labels [front]: "TOTAL MAXIMUM OUTPUT; 120VAC/5.0A MAX, 50/60 HZ/1037 PL/1139 RECP/1237 RECP/1336 RECP/513 RECP/210 RECP403 RECP/ALIGN MARK ON/FIBER TO/[downward arrow]". Mfr's labels [back]: "LASER POWER/0FF/0N/420 CNTR/[symbol electrical danger]/symbol for general danger]/419 S/SPECIAL INSPECTION/[logo]entala/H 081251/COMPLIES WITH THE/RELEVENT REQUIREMENTS/ OF THE APPLICABLE CSA/STANDARDS AND GUIDE-/LINES FOR INSPECTION OF/HEALTH CARE EQUIPMENT/THIS EVALUATION DOES NOT CONSTITUTE A CERTIFICATION [Also in French]/INPUT POWER: 120VAC/6.7A MAX/60HZ/REPLACE FUSE WITH 2 X 8.0A/250VAC/TIME LAG TYPE OR EQUIVALENT".
- Manque
- Nothing is missing.
- Fini
- Metal casing; synthetic grey cables; black synthetic connectors with metal hardware and orange synthetic cables with metal connectors.
- Décoration
- None.
FAIRE RÉFÉRENCE À CET OBJET
Si vous souhaitez publier de l’information sur cet objet de collection, veuillez indiquer ce qui suit :
Fabricant inconnu, Laser, Date inconnue, Numéro de l'artefact 2010.0304, Ingenium - Musées des sciences et de l'innovation du Canada, http://collections.ingeniumcanada.org/fr/item/2010.0304.010/
RÉTROACTION
Envoyer une question ou un commentaire sur cet artefact.